Owning Palette: Signal Manipulation Express VIs
Requires: Base Development System
Uses triggering to extract a segment out of a signal. The trigger conditions can be based on a start or stop trigger threshold or can be static. When a trigger condition is static, the trigger occurs immediately and this Express VI returns a predefined number of samples.
Dialog Box Options |
Block Diagram Inputs |
Block Diagram Outputs |
![]() |
![]() |
Parameter | Description | ||
---|---|---|---|
Start Trigger | Contains the following options:
| ||
Stop Trigger | Contains the following options:
| ||
General | Contains the following options:
| ||
Output segment size | Contains the following options:
| ||
Input Signal | Displays the input signal. If you wire data to the Express VI and run it, Input Signal displays real data. If you close and reopen the Express VI, Input Signal displays sample data until you run the Express VI again.
| ||
Results Preview | Displays a preview of the measurement. The Results Preview plot indicates the value of the selected measurement with a dotted line. If you wire data to the Express VI and run the VI, Results Preview displays real data. If you close and reopen the Express VI, Results Preview displays sample data until you run the VI again. If the cutoff frequency values are invalid, Results Preview does not display valid data. |
Parameter | Description |
---|---|
Manual Trigger | Starts the trigger immediately and overrides the Start Trigger settings you configure. The default is FALSE. |
Signals | Contains the input signal or signals. |
Data Index | Contains the index of the detected trigger. If this Express VI is in a loop, wire Data Index to the iteration terminal of the loop. |
Reset | Controls the initialization of the internal state of the VI. The default is FALSE. |
error in | Describes error conditions that occur before this node runs. |
Parameter | Description |
---|---|
Triggered Signals | Returns the resulting segment between Start Trigger and Stop Trigger. If no data meets the requirements of the trigger, this output returns an empty signal. |
Previous Signals | Contains the last triggered output data. If no data meets the requirements of the trigger, this output contains the most recent segment that meet the requirements of the trigger. |
error out | Contains error information. This output provides standard error out functionality. |
Data Available | Indicates if data is available that meets the requirements of the trigger. |
This Express VI operates similarly to the following VIs and functions:
Submit feedback on this topic.
Visit ni.com/support for technical support.