Scale Delta t VI

Owning Palette: Waveform VIs and Functions

Requires: Base Development System

Multiplies the delta t component of the waveform by the specified scale factor. Generally, this lengthens or shortens the sample rate of the waveform. The data type you wire to the waveform in input and the data type of the Y component of the analog waveform determine the polymorphic instance to use.

Use the pull-down menu to select an instance of this VI.

 Add to the block diagram  Find on the palette

WDT Scale Delta t DBL

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

WDT Scale Delta t SGL

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

WDT Scale Delta t I64

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

WDT Scale Delta t I32

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

WDT Scale Delta t I16

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

WDT Scale Delta t CDB

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

WDT Scale Delta t EXT

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.

DWDT Scale Delta t

waveform in is the waveform for which you want to scale the delta t. The default is empty.
scale factor is the number by which you multiply the waveform's delta t. A value of greater than zero but less than 1 shortens the sample rate. A value of greater than 1 increases the sample rate. The default is 1000.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
waveform out returns the resulting waveform with the new delta t value.
error out contains error information. This output provides standard error out functionality.