Owning Palette: Waveform VIs and Functions
Requires: Base Development System
Converts a digital waveform or digital data to analog waveform. You must manually select the polymorphic instance you want to use.
Use the pull-down menu to select an instance of this VI.
Add to the block diagram | Find on the palette |
digital waveform is the waveform you want to convert to analog waveform. | |||||||
full-scale range (pk-pk) specifies the total peak-to-peak range, or the difference between the minimum and maximum, for the digital waveform or digital data. For example, if the maximum range of a waveform is 1 and the minimum is –1, the full-scale range for the waveform is 2. The default is 2. | |||||||
error in describes error conditions that occur before this node runs. With the following exception, this input provides standard error in functionality.
If an error occurred before this node runs, this node outputs an empty waveform. |
|||||||
data format specifies which binary representation you want to use for the digital waveform or digital data.
|
|||||||
analog waveform returns the waveform resulting from the conversion of digital waveform or digital table. | |||||||
resolution (out) returns the number of bits represented in the digital waveform or digital data. | |||||||
full-scale range (out) returns the total peak-to-peak range for the digital waveform or digital data. | |||||||
error out contains error information. This output provides standard error out functionality. |
digital table is the digital data you want to convert to analog waveform. | |||||||
full-scale range (pk-pk) specifies the total peak-to-peak range, or the difference between the minimum and maximum, for the digital waveform or digital data. For example, if the maximum range of a waveform is 1 and the minimum is –1, the full-scale range for the waveform is 2. The default is 2. | |||||||
error in describes error conditions that occur before this node runs. With the following exception, this input provides standard error in functionality.
If an error occurred before this node runs, this node outputs an empty waveform. |
|||||||
data format specifies which binary representation you want to use for the digital waveform or digital data.
|
|||||||
analog waveform returns the waveform resulting from the conversion of digital waveform or digital table. | |||||||
resolution (out) returns the number of bits represented in the digital waveform or digital data. | |||||||
full-scale range (out) returns the total peak-to-peak range for the digital waveform or digital data. | |||||||
error out contains error information. This output provides standard error out functionality. |