Short Name: RespToValOutLimits.Inc
Requires: Base Development System
Class: Numeric Properties
To Use: Create a property.
Reads or writes the response to values outside the specified limits for the increment value.
You can select from the following options:
0 | Ignore—LabVIEW does not change or flag invalid values. |
1 | Coerce (to nearest) |
2 | Coerce up |
3 | Coerce down |
This property is an element of the Response to Value Outside Limits property.
This property is similar to the Response to value outside limits option on the Data Entry page of the Properties dialog box.
The following table lists the characteristics of this property.
Data type | |
Permissions | Read/Write |
Available in Run-Time Engine | Yes |
Available in Real-Time Operating System | Yes |
Settable when the VI is running | Yes |
Loads the front panel into memory | No |
Need to authenticate before use | No |
Loads the block diagram into memory | No |
Remote access allowed | Yes |