Short Name: RespToValOutLimits
Requires: Base Development System
Class: AbsTime Properties
To Use: Create a property.
Reads or writes the response to values outside the specified limits for maximum, minimum, and increment.
You can select from the following options:
| 0 | Ignore—LabVIEW does not change or flag invalid values. | 
| 1 | Coerce (to nearest) | 
| 2 | Coerce up | 
| 3 | Coerce down | 
This property is similar to the Response to value outside limits options on the Data Entry page of the Time Stamp Properties dialog box.
| Name | Description | 
|---|---|
| Response to Value Outside Limits:Minimum | Response to values outside the limits for the minimum value. Valid values include 0 (Ignore) and 1 (Coerce). | 
| Response to Value Outside Limits:Maximum | Response to values outside the limits for the maximum value. Valid values include 0 (Ignore) and 1 (Coerce). | 
| Response to Value Outside Limits:Increment | Response to values outside the limits for the increment value. Valid values include 0 (Ignore), 1 (Coerce to nearest), 2 (Coerce up), and 3 (Coerce down). | 
The following table lists the characteristics of this property.
| Data type | ![]()  | 
| Permissions | Read/Write | 
| Available in Run-Time Engine | Yes | 
| Available in Real-Time Operating System | Yes | 
| Settable when the VI is running | Yes | 
| Loads the front panel into memory | No | 
| Need to authenticate before use | No | 
| Loads the block diagram into memory | No | 
| Remote access allowed | Yes |