Butterworth Coefficients VI

Owning Palette: Advanced IIR Filtering VIs

Requires: Full Development System

Generates the set of filter coefficients to implement an IIR filter as specified by the Butterworth filter model.

You can pass these filter coefficients, IIR Filter Cluster, to the IIR Cascade Filter VI to filter a sequence of data.

Details  

 Add to the block diagram  Find on the palette
filter structure option specifies the order of the IIR cascade filter in IIR Filter Cluster.

0IIR 2nd Order—Returns IIR second-order filter stages.
1IIR 4th Order—Returns IIR fourth-order filter stages.
2Auto Select (default)—Returns either IIR second-order or IIR fourth-order filter stages according to the filter type. If filter type is Lowpass or Highpass, this VI returns IIR second-order filter stages. If filter type is Bandpass or Bandstop, this VI returns IIR fourth-order filter stages.
filter type specifies the passband of the filter.

0Lowpass
1Highpass
2Bandpass
3Bandstop
sampling freq: fs is the sampling frequency in Hz and must be greater than zero. The default is 1.0 Hz. If sampling freq: fs is less than or equal to zero, the VI sets Reverse Coefficients and Forward Coefficients to empty arrays and returns an error.
high cutoff freq: fh is the high cutoff frequency in Hz. The default is 0.45 Hz. The VI ignores this parameter when filter type is 0 (Lowpass) or 1 (Highpass). When filter type is 2 (Bandpass) or 3 (Bandstop), high cutoff freq: fh must be greater than low cutoff freq: fl and observe the Nyquist criterion.
low cutoff freq: fl is the low cutoff frequency in Hz and must observe the Nyquist criterion. If low cutoff freq: fl is less than zero or greater than half the sampling frequency, this VI sets Reverse Coefficients and Forward Coefficients to empty arrays and returns an error.
Note  All cutoff frequencies must be less than half the sampling frequency.
order is the order of the IIR filter and must be greater than zero. If order is less than or equal to zero, the VI sets Reverse Coefficients and Forward Coefficients to empty arrays and returns an error.
IIR Filter Cluster contains the cascaded form of IIR filter coefficients.
filter structure indicates either IIR second-order or IIR fourth-order filter stages.
Reverse Coefficients is the reverse coefficients of the IIR cascade filter.
Forward Coefficients is the forward coefficients of the IIR cascade filter.
error returns any error or warning from the VI. You can wire error to the Error Cluster From Error Code VI to convert the error code or warning into an error cluster.

Butterworth Coefficients Details

The Butterworth Coefficients VI is a subVI of the Butterworth Filter VI.