Requires: Base Development System
Class: VI Methods (ActiveX)
Calls the VI as a subVI. Optionally, you can open the front panel of the VI and close it after the call is over. You also can suspend the VI when called.
object.Call2([Param Names], [Param Values], [Open Front Panel], [Close Front Panel After Call], [Suspend On Call], [Bring App To Front])
Name | Type | Description |
---|---|---|
Param Names | array of strings by ref | Names of the LabVIEW front panel objects that act as input and output parameters to the call. |
Param Values | array of variants by ref | Input values for the input parameters and return values from the output parameters in the order in which the names were specified in paramNames. Designates the front panel object values for the input parameters. The values of parameters can be numeric, Boolean, string, or array. A cluster in LabVIEW is represented as an array of variants in ActiveX. |
Open Front Panel | Boolean | Opens the front panel of the VI. |
Close Front Panel After Call | Boolean | Closes the front panel of the VI after the call if the front panel was not already closed. |
Suspend On Call | Boolean | Suspends, or pauses the execution of, the VI on call. |
Bring App To Front | Boolean | Brings the application to the front. |
none